Product Information
| 191-TB01 | 191-ES01 |
|---|---|---|
Power Generation Output | 700 to 250W | |
Heat Output | 900 to 250W | |
Efficiency (Higher heating value) | Overall efficiency: Greater than 72% Overall efficiency: Greater than 54% | |
Efficiency (Lower heating value) | Overall efficiency: Greater than 80% Overall efficiency: Greater than 60% | |
Electrical Format | 3-wire single-phase 100/200V (50Hz/60Hz) | |
Type of gas | Uses City Gas 13A | |
Maximum gas consumption | 2.2kW (1,892kcal/h) *1 | |
External dimensions�imm�j | Height 895 * Width 890 * | Height 900 * Width 900 * |
Mass | 105kg | |
Noise level | 38dB*2 | |
Format | Polymer electrolyte | |
Regular inspection*3 period | Every 2 years | |
| 136-CF01 | ||
|---|---|---|---|
Water storage temperature | Approx. 60 degree centigrade | ||
Water storage tank capacity | 200 liters | ||
Water dispensing | Capacity | No. 24 | |
Pressure reduction valve pressure | 370kPa(3.78kgf/cm2) | ||
Supplementary heating | Capacity | 12.0kW(10,300kcal/h) | |
Home heating | Capacity | 17.4kW(15,000kcal/h)at high temperatures | |
Type of gas | Uses City Gas 13A | ||
Maximum gas consumption | 50kW(43,000kcal/h)*1 | ||
External dimensions(mm) | Height 1,900 * Width 750 * Depth 440 | ||
Mass(mass when full) | Approx. 105kg(Approx 305kg) | ||
Noise level*2 | 48dB <44dB when operating for home heating along> | ||
*1 “Maximum gas consumption” is shown based on a heat amount of 45.0MJ/m3 (10,750kcal/m3), and at a specific gravity of 0.638 for 13A City Gas.
*2 The noise level is calculated by Osaka Gas in an anechoic chamber.
*3 A regular two-yearly inspection is required. If inspections and maintenance are not carried out, operation of the fuel cell generation unit will cease after a set period of time.
Price (main unit + remote control)
¥3,255,000 (including tax)
Energy Saving and Environmentalism
Compared with existing systems (*1), primary energy consumption can be reduced by some 30%, and CO2 production levels by some 40%.
The amount of CO2 your household will be able to cut is about 1.3 tonnes annually (*2).
Economy
ENE-FARM can be used to generate electricity and heat without waste to operate most effectively to match your use patterns for electricity and heat (hot water and home heating).
So compared to existing systems (*3), you will be able to save about \50,000 per year (*2) in heating and electricity bills.
*1 The method where electricity is provided from the thermal power stations, and heat is provided from hot water and home heating devices that use natural gas provided by Osaka Gas for heat.
Compared with electricity generation at about 700Wh.
*2 Numbers based on Osaka Gas figures (single home, floor area of 150m2, 4-person family, appliances used: gas stove, gas hot water floor heater, gas hot water bathroom heater and dryer with mist sauna function)
*3 [Existing systems] Bring in hot water and home heating device. Household-use gas hot water home heating contract applies (options discount: 9%)
[ENE-FARM] Bring in ENE-FARM. Household-use co-generation system contract applies (options discount: 9%)
Location Spaces / Foundations / Waste Water